Görseller ürün eşleştirmesi için referanstır; sipariş öncesi model doğrulanır.
Ölçüm ışık perdeleri
XAORI-LCMF05 Measuring Light Curtain
Parça numarasıXAORI-LCMF05
Parça numarası, uygulama ve teknik beklentilerinizi paylaşın; ekibimiz uyumluluk, termin ve fiyat çalışmasını tek teklifte sunsun.
Teknik doğrulama
Global teslimat
Belgeli teklif
Teknik bilgiler
Katalog kaydı
- Parça numarası
- XAORI-LCMF05
- Kategori
- Ölçüm ışık perdeleri
- Marka
- Xaori Sensor
- Uyumlu model
- Xaori ölçüm ışık perdeleri, Xaori measuring light curtains
Teknik veri
Kaynak sayfaÜrün bilgileri
XAORI-LCMF05 series grating consists of transmitter and receiver. Beam synchronization adopts line synchronization method. The power supplies of the transmitter and receiver need to share the ground. The measurement results are output from the receiver, with two level outputs, two analog outputs, and a set of serial data outputs. Digital measurement results are accessed via serial communication. Simple settings can be done through the remote setting line (pink) or Android APP, and advanced settings and detailed data can be done through the PC on the computer.
| Electrical parameters | |
| Supply voltage | 24VDC±15% |
| Maximum power | 10W (without load |
| Response time | 24VDC±15% |
| OSSD dual output | 10W (without load 20ms |
| output feedback | 2 channels of PNP output; each channel drive load capacity 300mA external relay status feedback |
| Shell protection class | IP65 |
| Shell protection class | 0~55°C |
| Storage temperature | -20~55°C |
| Relative humidity | 15%~95% |
| Optical parameters | |
| Detection height | 455mm/52*50mm (section size of shell) |
| Detection distance | 10m (use with vertical reflector) |
| Number of optical axes | 24~480 |
| Optical axis spacing | 460mm |
| Effective aperture EAA | ±2.5. @3m |
| wavelength | 940nm |
| Anti-ambient light interference | >10,000Lux |
| synchronicity | Optical synchronization |
| Scan method | Straight sweep | one side scan | bilateral scan | ||||||
| low gain | high gain | Scan step | |||||||
| 1 | 2 | 4 | 8 | 16 | 32 | ||||
| Minimum detection object | 5mm | 10mm | 10mm | 10mm | 20mm | 30mm | 50mm | 90mm | 170mm |
| edge resolution | 5mm | 5mm | 2.5mm | 2.5mm | 2.5mm | 2.5mm | 2.5mm | 2.5mm | 2.5mm |
| Gain selection | low gain | high gain | ||||
| Scan method | Straight sweep | one side scan | bilateral scan | Straight sweep | one side scan | bilateral scan |
| Minimum detection object | 5mm | - | - | 10mm | 10mm | related to stepping |
| edge resolution | 5mm | - | - | 5mm | 2.5mm | Single edge 2.5mm/overall 5mm |
| Measurement type | Paraphrase | Scan Method Restrictions | Remark | |
| FBB | First Beam Blocked | The position of the first blocked beam | Straight Scan/Single Side Scan/bilateral scan | Beam Position Type |
| FBM | First Beam Made | The position of the first blocked beam | Straight sweep | |
| LBB | Last Beam Blocked | The position of the last blocked beam | Straight Scan/Single Side Scan/bilateral scan | |
| LBM | Last Beam Made | The position of the last guided beam | Straight sweep | |
| MBB | Middle Beam Blocked | The middle position of the first and last occluded beams | Straight Scan/Single Side Scan/bilateral scan | |
| TBB | Total Beams Blocked | Total number of blocked beams | Straight Scan/Single Side Scan/bilateral scan | Beam quantity type |
| TBM | Total Beams Made | Total number of guided beams | Straight sweep | |
| CBB | Contiguous Beams Blocked | Maximum number of continuously blocked beams | Straight Scan/Single Side Scan/bilateral scan | |
| CBM | Contiguous Beams Made | Maximum number of continuous on-beams | Straight sweep | |
| TRN | Transitions | Number of edges, conduction to blocking or blocking to conduction, regarded as an edge | Straight Scan/Single Side Scan/Bilateral Scan | other types |
| OD | Outside Dimension | Number of beams between the first occluded beam and the last occluded beam | Straight Scan/Bilateral Scan | |
| ID | Inside Dimension | Number of guided beams between the first blocked beam and the last blocked beam | Straight Scan/Bilateral Scan | |
| CFBB | Contiguous First Beam Blocked | The position of the first occlusion beam of the maximum continuous occlusion beam | Straight Scan/Single Side Scan/Bilateral Scan | |
| CLBB | Contiguous Last Beam Blocked | The position of the last occluded beam of the maximum continuous occlusion beam | Straight Scan/ Single Side Scan/ Bilateral Scan | |
| 01FBB | Object 1 First Beam Blocked | The position of the first occluded beam of object 1 | Straight Scan/Single Side Scan/Bilateral Scan | |
| 01LBB | Object 1 Last Beam Blocked | The position of the last occluded beam of object 1 | Straight Scan/Single Side Scan/Bilateral Scan | |
| 02FBB | Object 2 First Beam Blocked | The position of the first occluded beam of object 2 | Straight Scan/Bilateral Scan | |
| 02LBB | Object 2 Last Beam Blocked | The position of the last occluded beam of object 2 | Straight Scan/Bilateral Scan | |
| 03FBB | Object 3 First Beam Blocked | The position of the first occluded beam of object 3 | Straight Scan/Bilateral Scan | |
| 03LBB | Object 3 Last Beam Blocked | The position of the last occluded beam of object 3 | Straight Scan/Bilateral Scan | |