Feature ● Temperature detection of two-dimensional area: 8 × 8 (64 pixels) ● Digital output (capability of temperature value output) ● Compact SMD package (adaptively to reflow mounting) ● RoHS compliant Typical applications ● Home appliances (Microwaves and air-conditioners) ● Building automation (People counting, Air conditioning control) ● Home automation (People detection) ● Factory automation (Fault prevention)

Product nameNumber of pixelOperating voltageAmplification factorPart number
Infrared array sensor Grid-EYE64 (Vertical 8 × Horizontal 8 Matrix)3.3 VHigh gainAMG8833
Low gainAMG8834
5.0 VHigh gainAMG8853
Low gainAMG8854
ItemPerformance
High gainLow gain
Applied voltage3.3 V ± 0.3 V or 5.0 V ± 0.5 V
Temperature range of measuring object0 ℃ to 80 ℃ +32 ℉ to +176 ℉−20 ℃ ~ 100 ℃ –4 ℉ to +212 ℉
Operating temperature range0 ℃ to 80 ℃ +32 ℉ to +176 ℉−20 ℃ ~ 80 ℃ –4 ℉ to +176 ℉
Storage temperature range−20 ℃ to 80 ℃ –4 ℉ to +176 ℉−20 ℃ ~ 80 ℃ –4 ℉ to +176 ℉
ItemAbsolute maximum ratingsTerminal
Applied voltage−0.3 V to 6.5 VVDD
Input voltage−0.3 V to VDD +0.3 VSCL, SDA, AD_SELECT
Output sink current−10 mA to 10 mAINT, SDA
Static electricity (Human Body Model)1 kVAll terminals
Static electricity (Machine Model)200 VAll terminals
ItemPerformance
High gainLow gain
Temperature accuracyTypical ± 2.5 ℃ ±4.5 ℉Typical ± 3.0 ℃ ±5.4 ℉
NETD *1Typical 0.05 K (in 1 fps setting*2) Typical 0.16 K (in 10 fps setting)
Viewing angleTypical 60 °
Current consumptionTypical 4.5 mA(normal mode) Typical 0.2 mA(sleep mode)
Setup timeTypical 50 ms(Time to enable communication after setup) Typical 15 s(Time to stabilize output after setup)